2014年9月23日星期二

Considerations of hydraulic tube fittings

  In the hydraulic system, both the metal pipe fitting, hose fitting, or are prone to leakage problems. For card sets of pipe joints, mostly due to the pipeline by a larger force or impact, so that the card sleeve loose or pipe end surface deformation caused by leaks, you should check whether the card sets out of round, edge or without defects, whether the pipe ends in good condition and the extent of compression Hydraulic tube fittings  nut, but also eliminate the pipeline force. For flared fittings, mostly due to excessive flaring, substandard quality requirements or repeatedly demolished, resulting in flaring deformation or cracks caused by leaks, then you can be re-flared front amputated.  
  Pipeline installation: hydraulic tube fitting  to try to avoid the heat radiation and cooling water temperature is too high or too low spray and other place, conflict occurs when you install, you should make a small tube bassoon, low-pressure pipe so that the high-pressure pipe; pipe cross each other can not be contact should be separated by a certain distance. Installation Notes: moving or still in the pipeline are not excessive bending, can not bend at the roots, moved to the extreme position when the pipeline must not pull too tight, should be more relaxed; try to avoid torsional deformation of the pipe; pipe as far as possible away from heat radiating member, the necessary insulation board fashion.

没有评论:

发表评论