hydraulic tube fittings,hydraulic hose,hydraulic fittings is with a one-way valve, one is without a check valve. Application with check valve, check valve and the gas source is connected to the end, when you disconnect the check valve closes automatically when you turn on the activity side thimble-way valve is opened. Is the use of self-locking ball is embedded in the groove, while the locking balls from "tapered cylindrical ---" sleeves.
2013年9月2日星期一
Remove and disintegration of the input shaft and the rotor member subsequent steps:
Remove and disintegration of the input shaft and the rotor member subsequent steps(1) Check the pump and turbine wheel (blade resonance test)2) Remove the bearing condition by measuring the Hydraulic tube fittings Hydraulic tube fittings bearing clearance3) Check the scoop tube body wear.4) Check the fusible plug, if necessary, replaced with new parts(5) re-scrape back after bush loaded (if necessary grinding shaft)6) cleaning rotation within the housing product oil and dirt.